TRITON™ Pipe Fusion

How TRITON Works

  1. 1
    Control Unit for TRITON
    The Control Unit converts standard 110/120 VAC electrical current to DC electrical current, then generates a radio frequency (RF) signal.
  2. 2
    RF signal transferred
    The RF signal is transferred to the jaws of the Fuser and concentrated into a high-frequency electromagnetic field.
  3. 3
    Reaction of heat
    The pipe Fittings contain materials that react with the electromagnetic field, creating heat.
  4. 4
    Fusion
    The heat fuses the plastic pipe and Fitting together to form a hermetic weld.
  5. 5
    Indicator emerges
    As the pipe heats, the Fuse-Telâ„¢ indicator emerges on the Fitting to signal a completed weld.

TRITON In The News: Owners Give Geothermal HVAC a Chance for Rental Properties - National Driller magazine (page 24)